High axial load, modular UHV compatible stage with integrated limit switches. Travel ranges from 100 to 300 mm and can support loads up to 50 kg.

## Product details

- Product code: `VSM19-X`
- Category: [Linear](https://arunmicro.com/products/category/linearstages/)
- Made in the UK
- UK-based support

## Best for

Rigid, motorised ultra-high-vacuum positioning requiring 100 to 300 mm travel, integrated limit switches and a integrated d-sub connector.

Choose the VSM19-X for applications needing higher axial-load capability, particularly vertical or multi-axis arrangements using option HR.

The stage has a published centred load capacity of 50 kg. With option HR, the separately specified axial load capacity is 50 kg at 1000 Hz and 1 A phase current.

Two UHV limit switches and a 15-way D-sub connector are included as standard.

## Not suitable when

Do not apply the 50 kg HR axial-load rating to the standard configuration. Confirm the appropriate axial-load rating and operating conditions for the selected version.

For 50 mm travel, consider the VSM17-X. For travel above 300 mm, compare the VSM23-X or VSM30-X against the required load and rigidity.

The standard aluminium stage is bakeable to 150 °C, increasing to 200 °C with option SS. Fitting an optical encoder reduces the maximum temperature to 120 °C.

## Selection guidance

Choose the standard VSM19-X for 5 µm full-step resolution and a maximum speed of 15 mm/s.

Choose option HR for 1 µm full-step resolution and the published higher axial-load capacity, accepting a reduced maximum speed of 3 mm/s.

Compared with the VSM17-X, the VSM19-X is the relevant alternative when integrated limit switches, a 15-way connector or higher axial-load capability are priorities.

Assess payload, load offset, orientation, speed and duty cycle together. Do not assume that maximum load and maximum speed are available simultaneously.

## Compatibility and prerequisites

The VSM19-X is suitable for vacuum environments down to 1 × 10⁻¹⁰ mbar and can be combined with VSM17, VSM23 and VSM30 stages.

Use a compatible stepper motor drive, such as the AML SMD4, with the appropriate feedthrough, airside cables and in-vacuum cables.

AML supplies in-vacuum cables for the stage's 15-way D-sub connection. Confirm the complete pinout and cable configuration, including limit switches and motor temperature sensing.

For encoder-equipped stages, specify a compatible encoder interface, such as the appropriate SMD4-E configuration.

## Ordering guidance

Standard order codes: VSM19-X-100, VSM19-X-150, VSM19-X-200, VSM19-X-250 and VSM19-X-300.

Published options include:
- HR: 1 µm full-step resolution and increased axial-load capability.
- SS: stainless steel construction.
- ER: incremental encoder.
- EA: absolute encoder.
- R: radiation-hardened configuration.

The two limit switches and 15-way D-sub connector are standard features.

Provide quantity, travel, orientation, payload, load offset, speed, duty cycle, positioning requirements and bakeout temperature. Confirm the complete option code and stage-to-drive cable configuration with AML.

## Order codes

| Order code | Description | Price |
| --- | --- | --- |
| VSM19-X-100 | 100 mm Travel, 5 µm resolution | £5,232.00 |
| VSM19-X-150 | 150 mm Travel, 5 µm resolution | £6,066.00 |
| VSM19-X-200 | 200 mm Travel, 5 µm resolution | £8,076.00 |
| VSM19-X-250 | 250 mm Travel, 5 µm resolution | £8,276.00 |
| VSM19-X-300 | 300 mm Travel, 5 µm resolution | £8,543.00 |

## Overview

New AML UHV linear stage. 

Linear translation stage suitable for use in UHV. Can support centred loads of up to 50 kilograms. Standard travels from 100 to 300 mm. 5 µm resolution allows for precise in-vacuum motion.

- High axial load capacity with option HR.

- Integrated limit switches and 15-way D-sub connector featured as standard.

- Standard travels from 100 to 300 mm

- 5 µm resolution (1 µm for option HR)

- Maximum speed 15 mm/s (3 mm/s for option HR)

- Stackable for XYZ orientations

- Compatible with VSM17, VSM23, and VSM30 stages

- Suitable for use to 1 x 10-10 mBar

- UHV-prepared aluminium construction as standard

- Stainless steel construction available (option SS)

- Bakeable to 150°C (200°C for option SS)

## Key Features

Integrated VLS3 UHV Limit Switches:
- 2x UHV compatible limit switches integrated as standard.

Integrated D-sub Connector:
- Ease of connectivity with AML's in-vacuum cables. Multiple configurations available.

High axial load with option HR:
- 50 kg axial load with option HR.

## Documentation and downloads

- [Datasheet](https://arunmicro.com/documentation/Datasheet_VSM19-X.pdf)
- [Encoder Pinout Datasheet](https://arunmicro.com/documentation/Datasheet_Encoder_Pinout.pdf)
- [Operating Instructions](https://arunmicro.com/documentation/Manual_VSM19-X.pdf)
- [VSM19-X Drawing Pack](https://arunmicro.com/documentation/VSM19-X_Drawing_Pack.pdf)
- [VSM19-X Vacuum Performance](https://arunmicro.com/documentation/APN_VSM19-X_Vacuum_Performance.pdf)
- [VSM19-X-100 (.zip)](https://arunmicro.com/downloads/CAD_VSM19-X-100.zip)
- [VSM19-X-150 (.zip)](https://arunmicro.com/downloads/CAD-VSM19-X-150.zip)
- [VSM19-X-200 (.zip)](https://arunmicro.com/downloads/CAD-VSM19-X-200.zip)
- [VSM19-X-250 (.zip)](https://arunmicro.com/downloads/CAD-VSM19-X-250.zip)
- [VSM19-X-300 (.zip)](https://arunmicro.com/downloads/CAD-VSM19-X-300.zip)

## Related products

- [In-Vacuum Cables](https://arunmicro.com/products/in-vacuum-cables/): UHV compatible cables for connecting VSM19-X and VSM30-X stages
- [SMD4 Stepper Motor Drive](https://arunmicro.com/products/smd4-stepper-motor-drive/): Stepper motor drive optimised for use with AML UHV-compatible motors. Features advanced connectivity with USB, Ethernet and RS232/485 interfaces. Optional encoder module for incremental and absolute encoders
- [VSM Stage Mounting Brackets and Table](https://arunmicro.com/products/vacuum-stage-mounting-brackets/): Mounting Brackets For UHV Compatible Stages.
- [Stage Alignment Spigot](https://arunmicro.com/products/vacuum-stage-alignment-spigot/): Stage Alignment Spigot for VSM Stages.
- [Linear](https://arunmicro.com/products/category/linearstages/)
- [Rotation](https://arunmicro.com/products/category/rotationstages/)
- [Goniometer](https://arunmicro.com/products/category/goniometerstages/)